HPLC Column, Bidentate C8, 4um, 2.1mm ID x 100mm Length, 100A. Cogent TYPE-C Brand. 1 EA.

Additional Info:

The 40008‑10P‑2 Cogent Bidentate C8™ HPLC Column is a narrow‑bore, extended‑length analytical column designed for applications requiring greater resolution than 50 mm formats, while maintaining alternative reversed‑phase selectivity when C18 retention is excessive. Built on Cogent TYPE‑C™ silica hydride technology, this column delivers excellent selectivity, faster equilibration, and extremely robust column lifetimes compared with conventional silica‑based C8 columns.

The stationary phase consists of an aliphatic C8 hydrocarbon chain bonded via two direct silicon–carbon bonds (bidentate attachment) to a silica hydride surface. This chemistry produces a phase that is more hydrophobic than traditional C8 columns, yet less hydrophobic than Bidentate C18™, offering a controlled middle ground for method development. Unlike standard C8 phases, this column can also retain select hydrophilic compounds if desired and is stable at very low pH (below pH 2) without damage.

The 2.1 mm internal diameter supports low‑flow operation, reduced solvent consumption, and enhanced detector sensitivity, while the 100 mm length increases plate count and resolving power relative to 50 mm formats. As a result, this column is very popular for LC‑MS workflows when increased resolution is required without changing stationary phase chemistry.

Why Choose the 2.1 × 100 mm Bidentate C8™ Format

This column size is commonly selected when:

  • C18 columns provide excessive retention or long run times

  • Standard C8 columns do not deliver adequate resolution

  • Additional separation of closely eluting analytes is required

  • LC‑MS sensitivity and solvent‑use reduction are important

The extended length enhances resolution, while TYPE‑C™ silica hydride chemistry ensures fast equilibration and long service life.

Key Features

Cogent TYPE‑C™ Silica Hydride Technology

  • Non‑traditional reversed‑phase surface chemistry

  • Reduced silanol activity and secondary interactions

  • Faster equilibration than conventional silica‑based C8 columns

  • Extremely robust and reproducible column performance

Bidentate C8™ Bonding

  • Two‑point attachment via direct Si–C bonds

  • Balanced hydrophobic retention

  • Alternative selectivity when C18 is overly retentive

High‑Resolution Narrow‑Bore Geometry

  • 2.1 mm ID × 100 mm length

  • Higher resolution than 50 mm formats

  • Reduced solvent consumption

LC‑MS‑Ready Format

  • Optimized for low‑flow operation

  • Enhanced sensitivity for ESI‑MS and LC‑MS/MS

  • Requires precise low‑flow pumping and reduced‑volume flow cells

System Requirements

For optimal performance with this narrow‑bore column:

  • Use a pump capable of accurate and reproducible low‑flow delivery

  • Employ detector flow cells designed for low internal volumes

Typical Applications

  • LC‑MS and LC‑MS/MS

  • Hydrophobic and moderately polar compounds

  • Situations where C18 retention is excessive

  • High‑resolution reversed‑phase methods

  • Method development and optimization

 